1. Product description

The DeFelsko (USA) PosiTest AT measures the pull-off adhesion of coatings on metal, wood, concrete and other rigid substrates, in MPa or psi.

1. All models feature:

① Environmentally sealed housing – for use in all weather, dustproof and shock-resistant, meeting or exceeding IP65.

② Inexpensive disposable dollies – no cleaning for re-use, and they can be kept as a permanent record.

③ Conformity with international standards including ASTM D4541/D7234, ISO 4624/16276-1, AS/NZS 1580.408.5 and others.

④ A choice of 10, 14, 20 and 50 mm dollies to suit high or low bond strengths and improve resolution.

⑤ Every unit is calibrated and comes with a calibration certificate; accuracy is 1%, and the calibration sensor is traceable to NIST.

2. Self-aligning

① Automatically compensates for misalignment.

② Quick-coupling actuator aligns itself.   Image 1.png

③ Ball-joint coupling for the test.

④ Applies an even pull-off force across the surface.

⑤ Prevents one-sided pull-offs.

2. Model comparison

1. PosiTest AT-M (manual)

① Manual hydraulic pump gives smooth, continuous hydraulic pressure in a single stroke.

② Displays the pull rate, so it can be adjusted by hand.

③ Stores 200 results internally, including maximum pull-off pressure, pull rate, pull time and dolly size.

④ Compatible with PosiSoft software.

2. PosiTest AT-A (automatic)

① Electric hydraulic pump applies smooth, continuous pressure automatically, greatly reducing operator influence and the risk of affecting the test.

② Pull rate, pull limit and dwell time can be set.

③ Built-in rechargeable battery gives 200 tests per charge; tests can run on AC power while charging.

④ Stores maximum pull-off pressure, pull rate, pull time, dolly size, pass/fail, fracture condition and user notes – up to 100,000 results in up to 1,000 batches.

⑤ Compatible with PosiSoft software, PosiSoft.net and the PosiTector App.

⑥ PosiSoft USB drive – stored readings and graphs can be downloaded to a PC without special software.

⑦ WiFi connects to PosiSoft.net for software updates.

⑧ Rubber bumpers on both sides absorb shocks, prevent slipping and provide support.

⑨ Impact- and scratch-resistant colour display; keypad operation, with or without gloves.

⑩ Connects wirelessly to smart devices through a free app.

3. Ordering guide

Manual models

ATM20

0.7 – 20 MPa

100 – 3000 psi

ATM50

0.4 – 3.5 MPa

50 – 500 psi

Automatic models

ATA20

0.7 – 24 MPa

100 – 3500 psi

100 – 7550 N

ATA50

0.4 – 3.8 MPa

50 – 560 psi

100 – 7550 N

Dolly size

20 mm

50 mm

Typical applications

Coatings on metal

Coatings on wood, concrete

and plastics

Resolution

0.01 MPa (1 psi)

Accuracy

± 1% of full scale

4. Standard equipment

AT-A gauge (built-in rechargeable NiMH battery); AT-M with 3 AAA alkaline batteries

Charger, dollies, abrasive pads,

cutting tool, adhesive,

mixing card, cotton swabs

USB cable

Shoulder strap (AT-A)

Certificate traceable to NIST

Carrying case

5. Optional accessories

Dolly size

Measuring range

10 mm dolly

400 – 10,000 psi

2.8 – 70 MPa

14 mm dolly

200 – 6000 psi

1.4 – 40 MPa

20 mm dolly

100 – 3000 psi

0.7 – 20 MPa

50 mm dolly

50 – 500 psi

0.4 – 3.5 MPa

Note: 50 mm dollies need the optional 50 mm kit.

Manual models

ATM20

0.7 – 20 MPa

100 – 3000 psi

ATM50

0.4 – 3.5 MPa

50 – 500 psi

Automatic models

ATA20

0.7 – 24 MPa

100 – 3500 psi

100 – 7550 N

ATA50

0.4 – 3.8 MPa

50 – 560 psi

100 – 7550 N

Dolly size

20 mm

50 mm

Typical applications

Coatings on metal

Coatings on wood, concrete

and plastics

Resolution

0.01 MPa (1 psi)

Accuracy

± 1% of full scale